The internal and external structures of the air conditioner

The most common type of household air conditioner is the split wall-mounted unit, which consists of an indoor unit and an outdoor unit, connected by copper pipes, signal lines, and drainage pipes.

✅ Indoor unit (hung in the room)
External
Front panel (intake grille): When opened, the filter can be removed.
Filter: Filters dust and should be cleaned regularly.
Exhaust outlet + air guide plate (swing blades): Exhales cold air/heat air, swings up, down, left and right.
Display panel, remote control receiver
Side pipe openings: Connect copper pipes, wires, and condensate drainage pipes.

Internal
1. Evaporator (Indoor Heat Exchanger): Copper tubes + Aluminum fins. Absorbs heat during cooling, cools the air; releases heat during heating.
2. Axial Fan (Long Drum Fan Wheel): Sucks in room air, passes it through the evaporator, and then blows out the air.
3. Water Collection Pan + Drain Pipe: During cooling, water condenses in the air and flows down the pipes to the outside (blocked pipes will leak).
4. Electronic Control Board, Temperature Sensor: Receives remote control signals, measures temperature, and controls the overall operation of the machine.
5. Stepper Motor: Drives the air guide plate to swing.

✅ Outdoor Unit (Placed on the Outdoor Balcony/External Wall)
External
Metal casing, with heat dissipation fins on the sides/back, and an air intake cover on the front
Valve interface (high/low pressure stop valves): Connects the copper pipes between the indoor and outdoor units, the fluorine injection port is here
Terminal box cover: Connects the power supply and communication lines between the indoor and outdoor units

Internal
1. Compressor (heart of the air conditioner): Compresses the refrigerant, drives the refrigerant circulation, and variable-frequency units can adjust speed to save energy.
2. Condenser (exhaust unit heat exchanger): Copper tubes and aluminum fins. During cooling, it discharges heat to the outside air.
3. Axial fans: Large fan blades, quickly blowing over the condenser to dissipate heat.
4. Four-way valve (only for heating and cooling air conditioners): Switches the direction of the refrigerant flow, enabling the interchange between cooling and heating.
5. Throttle components: Capillary tube / Electronic expansion valve: Reduces pressure and temperature, controls the flow of refrigerant.
6. Capacitors, external unit motherboard, sensors, dry filter: Start, control, protect, filter impurities in the refrigerant.

✅ Connecting components (between the inside and outside)
Two copper tubes: Thick gas pipe, thin liquid pipe, for transporting refrigerant.
Signal lines: Communication between the indoor and outdoor units.
Drainage pipe: Specifically for draining condensate water from the indoor unit.

✅ Simple principle in one sentence
Cooling: The evaporator in the indoor unit absorbs heat → The refrigerant carries the heat to the outdoor unit → The condenser in the outdoor unit discharges the heat to the outside. Heating relies on the four-way valve to switch direction, and the heat exchange functions between the inside and outside are interchangeable.